Probe Service - "System cannot find the path specified" error prevents service from starting

Probe Service - "System cannot find the path specified" error prevents service from starting

Symptom

  • When launching the 360Probe service Installer.bat, some line shows the message : System cannot find the path specified.

Environment

  • Product : 360Live

  • Environment :

    • OS : Windows

  • 360Probe is deployed

Reproducing the issue (if applicable)

There is two ways to reproduce this issue, the first one goes like this :

- Copy the probe folder in a desired location.
- Right click on the 360Probe Service Installer.bat and click on Run as Administrator
- The prompt will show some System cannot find the path specified errors

The second way is:
- Copy the probe folder in a desired location (e.g. C:\Probe).
- Open the command line prompt from the search bar (or by using windows+r and typing cmd)
- In the command line then run "C:\Probe\360Probe Service Installer.bat"
- Execute the installer from this command line. 

Cause (if applicable)

This issue is caused by the way Windows keeps track of the current directory.

When we double click on the 360Probe service Installer.bat the installer will be executed in the folder it is located.
But if we click on Run as Administrator the current directory will be C:\Windows\Sytem32 and some command won't work with this directory.
If we open it from the windows search, the issue will be the same 

Resolution

  • To resolve this issue, you should just double click on the 360Probe Service Installer.bat instead of running it as Administrator


    • Related Articles

    • Unable to create system preferences directory

      Condition The Apache Tomcat server log returns the following error on start-up: Could not create system preferences directory. System preferences are unusable Solution Cause This error occurs if the server is started using a user or service account ...
    • Converting Oracle based MSU UNX to SSU fails with "driver could not be loaded error"

      Symptom When you launch a MSU to SSU conversion on a universe based on an Oracle ODBC connection. On WebPatform 2023.1.1 : The task ends in success When you retrieve the - Converted universe, you have an empty Data foundation On WebPlatform 2023.2 ...
    • Error : "Can't instanciate Webi Factory"

      Symptom When running WEBI jobs, the following error may be encountered: 2014-11-14 15:05:00 +0100 INFO Creating hash for CUID-ShortName/path universe link: done 2014-11-14 15:05:00 +0100 INFO Getting url 2014-11-14 15:05:00 +0100 INFO Found url ...
    • Error : "java.sql.SQLException: I/O Error: SSO Failed: Native SSPI library not loaded"

      Symptom When running a 360eyes job (from the CMC or the GUI), the following error is received: "The program failed to run and supplied the following information: com.gbs.a.h: Error during Database update/migration: com.gbs.a.h: Error during ...
    • "Invalid tag: FORMAT_DICT" error

      Symptoms After upgrading a BusinessObjects (BOBJ) environment, you may encounter the error with 360Suite feature like 360Cast or 360Bind: Unexpected exception: Failed to parse document. Invalid tag: FORMAT_DICT These features typically work with ...